FAI
System Details:
The FAI System is an Electronic
Fresh Air Intake Control System that was conceived for
consumers with air tight homes or new construction.
Although the installation is basically the same as any
air exchanger; it's concept has been totally
revolutionized in order to meet all the expectations of
consumer demands.
To emphasize this point, we will
enumerate all the different changes and the reason
behind them:
A) The Fan: This is the
most important part of this product. By choosing our
fan, we took in consideration it's durability and the
amount of noise it produced at low levels of operation.
Although all fans produce what is called wind sound;
ours does not have an electrical resonance at low speed
(we use a transformer) which can become annoying to the
consumer. The quality with which our fan is produced is
backed up by the 10 year warranty that we issue with
confidence.
B) The Sensor: Our
temperature sensor will control the good function of the
system by comparing the temperature inside the dwelling
to outside and temper as best as possible, the air
coming into the dwelling by heating the air entering.
C) Electronic Board: There
is an electronic board which is pre-programmed to three
different applications of high speed. It controls the
amount of heating needed to heat the air coming in. The
diffusion of air is on three different applications:
1) 115 CFM,
2) 145 CFM,
3) 245 CFM.
The control of heated air is based
on a 20°C
(68°F)
household comfort zone. If the outside temperature is
less than this, the built-in heater will heat the air at
the entry level. The system maintains a regular low of
80 CFM
D) Filtration: The FAI
System is equipped with a filter which is up to 60%
efficient against air pollution. At that level the
filter is quiet affordable. A HEPA filter is available
on request.
E) Flexibility: The design
of the unit makes the installation very flexible.
F) Weight: The weight of
this unit is only twenty eight pounds (23 lbs),
therefore the freight cost is less for the consumer and
is easier to handle, both by the dealer and the
consumer.
G) Size: The FAI System is
approximately one cubic foot (1' x 1' x 1.5'). This
product can be installed in almost any place because it
is so small.
H) Air Changes: The
consumer has a choice between 3 different top speed air
changes:
1) One high speed air input
every hour for 15 minutes, or
2) One high speed air input
every hour for 30 minutes, or
3) One high speed air input
every hour for 45 minutes.
I) Humidity Sensor: This
unit is equipped with a Humidity Sensor which will
regulate the flow speed of air during cold dry periods
so that the unit cannot go on high speed when the air is
dry, thus avoiding situations where excessive dryness
could cause floor cracks and nose bleeds. It will also
minimize the cost of heating the air coming in.
Technical Data
Voltage: 110/220 volts
Energy Consumption: Fan: 90 watts
Heater: 1200 watts (floating)
Fan Frequency: 60 HZ
Fan RPM: 2600
Noise Level: 65 dBA
Filtering Efficiency: 50-60% of
all Particles
Height: 12 in
Width: 12 in
Depth: 19 in
Weight: approximately 23 lbs
Air Flow: 245 CFM
Serviceable area capacity: 2400 -
4000 sq. ft. Per unit
Patent Pending
Safety Features
Fan: Impeller Met-Plas UL
Heater: - Automatic cut-out at
30°C
(86°F)
- 2nd automatic
cut-out at 49°C
(120°F)
- 3rd cut-off at49°C
(120°F)
Filter
Carbon filter removes odors &
contamination
Prefilter - extends the life of
the carbon filter and absorbs more dust particles.
Characteristics & Highlights
- Small and compact - Flexible
in its installation,
- Heats the air coming in, thus
preventing cold drafts and the need to shut off the
system during cold weather,
- Less costly than heating cold
air from cold air exchangers and heated by control
heating system of a household,
- Encourages the use of Fresh
Air all year round,
- No complicated control panels,
- Less expensive air filters,
- One unit with multiple
choices, instead of multiple units with one choice,
- Dedicated unit to a specific
application; Temperature controlled Fresh Filtered Air
- Cycles per hour: 15, 30, 45
minutes of high speed selected,
- 3 speed fan, quiet operation,
- Reduce humidity by heating the
air coming in,
- Electronic control of heater
preset at a certain set point to control heated air
coming in,
- 2 Safety thermostats built in
for protection,
- Automatic shut down of heater
when not required,
- Manual shut down of heater,
- Parameters of unit are not
accessible by user, but can be changed and monitored for
performance by using a PC computer and program cable
uinit.
|